Dear Team,We are looking for replica of plant Solvent recovery column in R &D.Reboiler capacity : 3-5LtColumn Ht: 1.5-2mColumn Dia : VTS ( based on suitability).Column Pack : Raschid rings/ regular packing / etc;Moc: GlassReceivers: 02 (2.0Lt capacity)Operating conditions:Temperature: -20 to 200 deg C.Pressure : 0.5Kg/cm2.Vacuum: Full Vacuum and atmospheric distillation. Sampling points for solvents:Reflux ratio: VTS.Temperature sensors: (Temperature probe at Bottom, middle & Top of the column)- Mass Temperature- Vapor temperatureHot bath : Required.Atomization : Accepted for maximum allowed parameters. ( Mutual discussion).Spare Flask for Feed, Reboiler & Distillate.Safety interlock ( if any)Whether utility will be separate??? Can u provide Set up along with utility ( Single fluid unit)